Description:
How to configure and connect GP60A reader to PRxx2 series controller?
Solution:
1. Data transfer format - Magstripe:
Wires description:
Data - green,
Clock - white,
GND - black,
+12V - red.
Settings:
Operation mode selection: orange + yellow.
Reader type (option in the controller): [31] Magstripe, provides card coder.
OR
2. Data transfer format - Wiegand 26:
Wires description:
Data - white,
Clock - green,
GND - black,
+12V - red.
Settings:
Operation mode selection: white (Data) + yellow.
Reader type (option in the controller): [4] Wiegand 26...66 bit, provides card code.